OTNS8600-DCI4

OTNS8600-DCI4 Stackable Ultra 100G WDM Transmission Platform

Description

Product specifications

Parameter Description
Chassis Dimensions (H x W x D) 1U: 44 mm (H)×444 mm (W)×490 mm (D)
Maximum capacity 1.6Tbit/s
Number of service card slots 4
Applicable cabinets 19’’ cabinet 800mm or deeper
Line-side port Rate ⚫ 200G (PDM_QPSK)

⚫ 200G (PDM_8QAM)

⚫ 200G (PDM_16QAM)

⚫ 400G (PDM_16QAM)

Parameter Description
  Optical module Pluggable CFP2, wavelength adjustable
Client-side port Service type 10GE, 100GE, 100GE FlexE(Unware), OTU2, OTU4, STM-64, 10GE WAN
Optical module ⚫  Pluggable SFP+

⚫  Pluggable QSFP28

Max. number of wavelengths Fixed grid: 96 wavelengths @50 GHz
Channel spacing Fixed grid: 50 GHz / 75 GHz / 100 GHz / 150 GHz
Central frequency range 191.35 GHz ~ 196.1 GHz
Central wavelength range 1528.77 nm ~ 1566.73 nm
Protection function ⚫ Optical line protection (OLP)

⚫ Optical multiplexed segment protection (OMSP)

⚫ Optical channel protection (OCHP)

Network management ⚫ Supports CLI, NETCONF and B/S based GUI management platform

⚫ Support OSC based DCN communication

Power supply Back-up Standard CRPS power supply 1+1 backup
AC ⚫ Rated voltage range:

–       100 V AC~130 V AC (50/60Hz)

–       200 V AC~240 V AC (50/60Hz)

⚫ Max. voltage range: 90 V AC~264 V AC (45Hz~65Hz)

HVDC ⚫ Rated voltage range: 240 V HVDC

⚫ Max. voltage range: 192 V HVDC~288 V HVDC

DC ⚫ Rated voltage range: -48 V DC/-60 V DC

⚫ Max. voltage range: -40 V DC~-72 V DC

Heat dissipation ⚫ Front inlet air and rear outlet air

⚫ 1+1 Fan units backup

Typical power consumption <550W (Electric layer full match)
Environment Operating temperature ⚫ Short-term: -5℃~+45℃

⚫ Long-term: 0℃~40℃

Storage temperature -40℃~+70℃
Humidity   5%~95% (no condensation)